Dry eye disease is diagnosed from multiple angles based on various indicators, including tear film secretion evaluation, tear film stability assessment, meibomian gland dysfunction analysis, tear film distribution diagnosis, tear film color and pattern evaluation, blink interval measurement, corneal and conjunctival redness levels, and OSDI self-assessment questionnaire. Non-contact precision measurements and visualized reports enable accurate cause analysis and personalized treatment planning.
Using Placido Disc-based analysis technology, it precisely measures detailed corneal data such as curvature and shape, pupil size and response, refractive power variations, and corneal size. The reliable data is widely used in various clinical fields, including early diagnosis of keratoconus, vision distortion analysis, pre-refractive surgery evaluation, lens prescription and fitting.
The corneal topography analysis and dry eye diagnosis are integrated into one device, providing a comprehensive evaluation of eye health. Based on precise corneal diagnosis and tear film condition analysis, accurate causes are identified, enabling the prevention and treatment of corneal diseases and dry eye, as well as the prevention of vision deterioration. Additionally, it supports long-term vision maintenance and ocular health through pre- and post-surgery management.
The 90-degree rotating LCD, Foot Switch, wide headrest, Auto Tracking, and sound guide provide an optimal examination environment, enhancing the examiner's convenience. The built-in PC allows for seamless monitoring of all processes, from measurements to detailed analysis reports for accurate evaluations. Additionally, compatibility with HIIS-1 and DICOM further improves clinical efficiency.
Parameter
Measuring range
SD of Repeatability
Corneal curvature radius
3 – 38mm
±0.03 mm
Cornea refractive power
9D~110D (Cornea equivalence’s refractive index: 1.3375)
Direction of principal meridians
Measuring range: 1° – 180°, Accuracy: according to the ISO 10343:2014
White-to-white distance
7 – 14mm
±0.05 mm
Pupil diameter
0.5 – 10mm
±0.05 mm
Working distance
80~100 mm
Placido disc
24 rings
Points Analyzed
Over 100,000 (Measured points:Over 6,220)
Measuring accuracy
Type A according to the ISO 19980:2012
Measuring range
up to Ø 9,8 mm (on a 8 mm sphere) 42,20D with n=1.3375
Display
Swiveling & Tiltable 10.1 inch, Touch panel color LCD
Horizontal movement
55 mm (back and forth), 100 mm (left and right)
Vertical movement
30 mm
Chinrest movement
62 mm (up and down), motorized
Auto tracking
X,Y for positioning, Z for working distance
Power supply
AC 100–240 V, 50/60 Hz, 1.6–0.7 A
PC
Built in computer
Dimensions
312(W) x 553(D) x 518(H) mm
Mass
19 kg
Topography
Keratoconus
Contact lens fitting
Zernike Analysis
Pupillometry
White To White
Lipid Layer
Tear Meniscus Height
NIKBUT
Meibomian
Redness
Questionnaire(OSDI)
Keratoscopy(Fluorescein & Imaging)
* Specification and design are subject to change without notice.